10 exam-style questions with answers and explanations, straight from our 1,030-question bank. Tap an answer to check yourself. When you're ready, take the scored version in the free practice test.
These 10 free CT-PEST questions are organized by exam domain, so you can see how each part of the Connecticut Commercial Pesticide Applicator Core Exam blueprint is tested. Reveal the answer and explanation under each question.
Domain 2: Federal Pesticide Laws and Regulations
Question 1
A supplier offers an EPA-registered herbicide that has not been registered in Connecticut. No registration exemption applies. The proposed turf use is on the label, and the commercial crew has the appropriate certifications. The supplier argues that federal registration is sufficient. Which statement correctly resolves the issue?
Show answer & explanation
Correct answer: A - EPA registration does not substitute for Connecticut product registration.
Domain 3: Pesticide Labeling
Question 2
A work order covers a 12,000-sq-ft property but excludes 3,000 sq ft of pavement and a 1,500-sq-ft flowering buffer. The remaining turf is to receive 2 fl oz of product per 1,000 sq ft. At the operating settings to be used, clean-water calibration delivers 1 gallon of spray per 1,000 sq ft. The tank holds 15 gallons. Which batch supplies only the amount needed for the assigned area?
Show answer & explanation
Correct answer: A - 15 fl oz of product, with water added to make 7.5 gallons of final spray.
Domain 4: Pesticide Formulations
Question 3
Concentrate splashes into an operator's eye while mixing. An eyewash is within reach, and a coworker has the product label and a phone. The operator is wearing contact lenses. The label directs gentle water rinsing for 15-20 minutes, with contact lenses removed after the first 5 minutes. Which response should begin immediately?
Show answer & explanation
Correct answer: B - Start rinsing; remove the lens after 5 minutes and continue while the coworker obtains poison-control advice.
Question 4
A customer finds a toddler holding opened anticoagulant rodenticide bait. The amount, if any, swallowed is unknown. The child is alert, breathing normally, and has no symptoms. The customer calls the applicator for advice. What is the appropriate response now?
Show answer & explanation
Correct answer: C - Contact Poison Control now; clotting effects can be delayed even when a child initially appears well.
Domain 5: Pesticide Hazards and First Aid
Question 5
Four identical boom nozzles have been cleaned and tested with water at the same specified pressure. Their outputs are 0.39, 0.40, 0.41, and 0.48 gallon per minute. The manufacturer's reference output is 0.40 gallon per minute, and its instruction is to replace any nozzle exceeding that output by more than 10%. Which correction addresses the application-uniformity problem?
Show answer & explanation
Correct answer: D - Replace the 0.48-gallon-per-minute nozzle and recheck the outputs.
Domain 6: Personal Protective Equipment
Question 6
A locked storage room meets the pesticides' temperature and ventilation requirements. Original containers are upright and clearly labeled, but bags of animal feed occupy the shelf beneath liquid pesticides. What change addresses the remaining contamination hazard?
Show answer & explanation
Correct answer: B - Move the animal feed to storage separate from the pesticides.
Domain 7: Pesticides in the Environment
Question 7
The morning after an insecticide application, several unrelated ornamental plant species show leaf injury within a sharply defined spray strip. Plants of the same species just outside the strip are healthy. The sprayer had previously contained a herbicide, and the crew did not perform the required cleaning before changing products. What explanation should lead the supervisor's investigation?
Show answer & explanation
Correct answer: D - Phytotoxicity from residual herbicide in the spray equipment.
Question 8
A warehouse IPM program uses comparable 24-hour trap checks. Its action threshold is a mean of 3 identified cockroaches per trap. After leaks are repaired and harborage removed, the current mean remains 5.2. The supervisor authorizes targeted bait placement. A manager objects that using an insecticide would abandon IPM. Which approach is consistent with IPM?
Show answer & explanation
Correct answer: A - Use the authorized bait while maintaining sanitation and comparable monitoring.
Domain 8: Transportation, Storage, and Security
Question 9
A turf insecticide label permits 1-3 fl oz per 1,000 sq ft per application, a maximum of 8 fl oz per 1,000 sq ft per year, and at least 14 days between applications. The lawn has received 5.5 fl oz per 1,000 sq ft this year; the last application was 21 days ago. The supervisor's written instructions specify 2 fl oz per 1,000 sq ft today. With all other use conditions satisfied, which treatment is authorized?
Show answer & explanation
Correct answer: B - Apply the specified 2 fl oz per 1,000 sq ft.
Domain 9: Emergency or Incident Response
Question 10
Before a Connecticut commercial application, a Junior Operator downloads complete, site-specific written instructions to a phone. They remain readable offline and can be transmitted to an inspector on request. The label does not require the supervisor's physical presence. The supervisor is immediately reachable and can arrive within 75 minutes if contacted. How does Connecticut's supervision rule apply to this arrangement?
Show answer & explanation
Correct answer: C - The operator may proceed using the accessible electronic instructions.